Standard step height: 7¾ in max, by code
Standard step height for home stairs is 7¾ in at most, with treads at least 10 in deep (IRC). Plus nosing, headroom, width, and rise and run.
By the TapePal teamUpdated 5 min read

Short answer
7¾ in is the most a step can rise in a US home under the IRC (R311.7.5.1), and each tread must be at least 10 in deep, nosing to nosing. In commercial buildings the IBC sets risers at 4 to 7 in and treads at 11 in or more. Headroom is at least 6 ft 8 in.
What is the standard step height?
In a home, a step can rise 7¾ in at most, under the International Residential Code (IRC), the model code for US homes. Commercial buildings follow the IBC, which caps risers at 7 in.
| What | Homes (IRC) | Commercial (IBC) | cm (homes) |
|---|---|---|---|
| Riser height | 7¾ in max | 4–7 in | 19.7 max |
| Tread depth, nosing to nosing | 10 in min | 11 in min | 25.4 min |
| Nosing | ¾–1¼ in (none needed if treads are 11 in+) | See IBC 1011.5.5 | 1.9–3.2 |
| Riser or tread variation in a flight | 3/8 in max | 3/8 in max | 1.0 max |
| Headroom | 6 ft 8 in min | 80 in min | 203 min |
| Width | 36 in min | 44 in min (36 in under 50 people) | 91 min |
Your town may have adopted an older code or its own changes, so check with your building department before you build or remodel a stair.
How do you work out stair rise and run?
Start with the total rise, floor to finished floor, then split it into equal steps:
- Count the risers: divide the total rise by 7¾ and round up.
- Size each riser: divide the total rise by that number.
- Count the treads: a straight flight has one fewer tread than risers.
- Total run: multiply the treads by the tread depth.
Say the total rise is 105 in. 105 ÷ 7¾ = 13.5, so you need 14 risers of 105 ÷ 14 = 7½ in. That gives 13 treads, and at 10 in each the stair runs 130 in, or 10 ft 10 in, across the floor.
What makes a comfortable step?
A rule of thumb, not a code: twice the riser plus the tread should come to about 24 to 25 in (2R + T). A 7 in riser and an 11 in tread give 25 in, a gentle step. A 7¾ in riser with a 10 in tread gives 25½ in, the steepest a home stair can be.
How much headroom and width does a stair need?
At least 6 ft 8 in of headroom in a home (IRC R311.7.2), measured straight up from the sloped line that joins the nosings. The stair must be at least 36 in wide (R311.7.1), and handrails may stick out up to 4½ in into that width on each side.
The handrail itself goes 34 to 38 in above the nosings. The rules for rails and guards are in stair railing height.
How do you measure stairs?
Measure one step at a time: the rise from the top of one tread to the top of the next, and the run from nosing to nosing. Then check the total rise, the width and the headroom against the table above.
- Measure the rise Hold the tape plumb on top of one tread and read the height to the top of the next tread. Do it on a few steps: they should match within 3/8 in.
- Measure the run Measure level from the front edge (nosing) of one tread to the nosing of the next. That is the tread depth the code means.
- Measure the total rise For a new stair, measure floor to finished floor, straight up. Divide by 7¾ and round up to get the number of risers.
- Measure the width and headroom Measure the width from wall to wall, or wall to the open side. For headroom, measure straight up from the nosing line to the lowest point of the ceiling above.
Carpeting the stairs? How to measure stairs for carpet covers treads, risers and nosings for an order.
Can your iPhone measure it?
Questions
What is the 7-11 rule for stairs?
A 7 in riser with an 11 in tread: the IBC limits for commercial stairs. It makes a gentle step at home too, but the IRC allows up to 7¾ in risers and 10 in treads.
Can stair risers be different heights?
Only by a little. In a home, the tallest and shortest riser in one flight can differ by no more than 3/8 in (IRC R311.7.5.1). The same goes for tread depths.
Do stairs need a nosing?
On a home stair with solid risers and treads less than 11 in deep, yes: ¾ to 1¼ in. With treads 11 in or deeper, the IRC doesn't require one.
How many steps for an 8 ft ceiling?
Say the ceiling is 8 ft and the floor above adds about 9 in of framing and flooring: about 105 in floor to floor. 105 ÷ 7¾ = 13.5, so 14 risers of 7½ in. Measure yours: framing varies.
How we checked this. Home stairs: IRC 2021 R311.7.1 (width 36 in), R311.7.8.2 (handrails may project 4½ in each side), R311.7.2 (headroom 6 ft 8 in), R311.7.5.1 (risers 7¾ in max, 3/8 in variation), R311.7.5.2 (treads 10 in min) and R311.7.5.3 (nosing ¾ to 1¼ in, not required with treads of 11 in or more). Commercial stairs: IBC 2021 1011.2 (width 44 in, 36 in for fewer than 50 occupants), 1011.3 (headroom 80 in) and 1011.5.2 (risers 4 to 7 in, treads 11 in min). The 2R + T rule is a rule of thumb, not code. Codes vary by town; check with your building department. Read 26 Nov 2026. Reviewed by the TapePal team on .